PR231A-1 multifunction calibrator detection equipments




Price Unavailable



  • Description
  • Details
  • Reviews
  • Panran

PR231A-1 Portable multifunctional process calibrator

The PR231 series products have excellent performance indicators, numerous practical functions and powerful human-computer interaction capabilities. The product covers two accuracy levels of 0.01 and 0.02. The measurement and output circuits are completely isolated. In addition to the common functions of the common two-channel calibrator, it also has the functions of p-value measurement and standard temperature measurement. The reluctant configuration also has a temperature difference test and a precision temperature control function. Compact design and easy to carry, suitable for on-site and laboratory applications, it is the first choice for the temperature measurement industry.

 

multifunctional process calibrator Features

1. Temperature difference measurement with accuracy of 0.003 ° C

The PR231A calibrator measures the temperature difference between two points in space without the aid of other instruments. When the function is used, the four terminals of the output function are multiplexed into measuring terminals in the device. The temperature difference data acquisition can be completed within 0.4 seconds, which effectively improves the measurement accuracy. During the test, the 10-minute volatility during the test can also be calculated in real time. Before using the standard platinum resistance or standard thermocouple for measurement work, the measurement results can be traced through the input of the certificate value and meet the requirements of the thermostat test specification for the electrical test instrument.

 

2. reference end compensation

The reference compensation method of PR231 series calibrator is very flexible. It can be selected: built-in, external, and custom. The external reference terminal adopts Class A Pt100 platinum resistance, and can input the certificate value for data correction of the reference end. PR231 The series calibrator is used in combination with the PR1501 type temperature compensation module to obtain a reference compensation error of less than 0.07 °C.

 

3. Precision temperature control

Using the precision temperature control function, temperature closed-loop control of the constant temperature equipment can be realized instead of the high-precision PD controller. In the case of constant temperature equipment and grid voltage, the temperature fluctuation of the equipment can be better than 0.02 ° C / 10 minutes (thermostat).

 

4. p value measurement

PR231 series calibrator can measure the duty cycle of periodic square wave signal, can be used to verify and calibrate the PID parameters of various digital temperature indicating regulators with time proportional output, and meet the "JG617-1996 digital temperature indicating regulator" "The requirements of the procedure.

 

5. Thermal calculator

Used to achieve mutual conversion between various power and temperature, supported by electricity

Types of volume and temperature conversion include: working thermocouples, industrial thermal resistance

And a variety of temperature transmitters.

 

6. Numerical setting method

PR231 series calibrator has the most flexible and convenient output value setting Setting mode, you can directly set the output value through the numeric keypad, or you can pass The direction keys are incremented by bit. In addition, the device also has a The step or ramp value setting method.

 

7. Sinusoidal signal output function

The verification/calibration of some process recorders (especially mechanical recorders) usually involves the operation of the test. At this time, the device's sinusoidal signal output function can be used to signal the meter.

 

8. Data logging function

The logging function saves measurement and output data. The PR231 series calibrator has powerful record management functions. Up to 32 device numbers can be created. Each device number has 16 record pages. Each record page contains four basics: time, measured value, output value and custom value. information. Users can perform device management, record deletion, etc. according to their needs.



  

Multifunction Process CalibratorGeneral technical parameters


Weight

990g

charging power

100~240V AC,50~60Hz

Size

225mm*130mm*53mm

Working temperature

-10℃~50℃

Cell type

7.4V 4400mAh, Rechargeable lithium battery

Working hours

Over 20 hours(Turn off 24V power supply)

Preheating time

10 minutes after preheating

Humidity

0~80%,Non condensing

Charging time

5 hours

Calibration period

1 year

 

Multifunction CalibratorModel selection table

Model

PR231A-1

PR231A-2

PR231B-1

PR231B-2

enhancement model

 

 

 

 

basic model

 

 

 

 

0.01 grade

 

 

 

 

0.02 grade

 

 

 

 

 Multifunction CalibratorMeasurement Accuracy

Items

Range

Measurement range

Resolution

0.01 accuracy

0.02 accuracy

Remarks

Voltage DC

100mV

-5mV~120mV

0.1uV

0.005%RD+5uV

0.015%RD+

5uV

Input impedance

≥80mΩ

1V

-50mV~1.2V

1uV

0.005%RD+0.005%FS

0.015%RD+

0.005%FS

10V

-0.5V~12V

10uV

Input impedance

≥1mΩ

50V

-0.5V~50V

0.1mV

Current DC

50mA

-5mA~50 mA

0.1uA

0.005%RD+0.005%FS

0.015%RD+

0.005%FS

Internal resistance =10Ω

Resistance

50Ω

0Ω~50Ω

0.1mΩ

0.005%RD+5mΩ

0.015%RD+

5mΩ

Output 1mA current

500Ω

0Ω~500Ω

1mΩ

0.005%RD+0.005%FS

0.015%RD+

0.005%FS

5kΩ

0kΩ~5kΩ

10mΩ

Output 0.1mA current

Thermal couple

S,R,B,K,N,J,E,T,EA2,Wre3-25,Wre5-26

0.1℃

Table 1

According to ITS-90 scale

Cold end compensation

Internal

-10℃~60℃

0.01℃

0.5℃

0.5℃

External

0.1℃

0.1℃

Thermal resistance

Pt10,Pt100, Pt200,Cu50,Cu100,BA1,BA2,JPt100, Pt500, Pt1000

0.01℃

Table 2

Standard temperature

S,R,B,T,SPt25,SPt100

0.01℃

Table 3

Need to enter the correction value

ρ-value

50S

0.001%~99.999%

0.001%

0.005%

0.005%

Input pulse width amplitude range:1V~50V

Frequency

10Hz

0.001Hz~12 Hz

0.001Hz

0.01%FS

0.01%FS

1kHz

0.00001kHz~1.2 kHz

0.01Hz

100kHz

0.01kHz~120 kHz

10Hz

0.1%FS

0.1%FS

Temperature difference

S,R,B,K,N,J,E,T

0.01℃

Table 4

Need to enter the correction value

SPt25,SPt100

0.001℃

 

Multifunction CalibratorSource Accuracy

Items

Range

Measurement

range

Resolution

0.01 accuracy

0.02 accuracy

Remarks

Voltage DC

100mV

-20mV~120mV

1uV

0.005%RD+5uV

0.015%RD+5uV

Maximum load current =2.5mA

1V

-0.2mV~1.2V

10uV

0.005%RD+0.005%FS

0.015%RD+0.005%FS

10V

-2V~12V

0.1mV

Current dc

30mA

-5mA~30 mA

1uA

0.005%RD+0.005%FS

0.015%RD+0.005%FS

Maximum load voltage =24V

Resistance

50Ω

0Ω~50Ω

0.1mΩ

Table 5

According to ITS-90 scale

500Ω

0Ω~500Ω

1mΩ

5kΩ

0kΩ~5kΩ

10mΩ

Thermal couple

S,R,B,K,N,J,E,T,EA2,Wre3-25,Wre5-26

0.1℃

Table 1

Thermal resistance

Pt10,Pt100, Pt200,Cu50,Cu100,BA1,BA2,

JPt100, Pt500, Pt1000

0.01℃

Table 6

Frequency

10Hz

0.001Hz~

12 Hz

0.001Hz

0.01%FS

0.01%FS

Maximum load current =2.5mA

1kHz

0.00001kHz~

1.2 kHz

 

0.01Hz

100kHz

0.01kHz~120 kHz

10Hz

0.1%FS

0.1%FS

Precision temperature

control

S,R,B,K,N,J,E,T

0.01℃

Table 7

Pt100

24V output

Maximum voltage error: 0.3V   Ripple noise:35mVp-p(20MHz bandwidth)

Maximum load current:70mA  Load regulation: 0.5%(10% -100% load change)

  • Model: PR231A-1
  • Shipping Weight: 2.4lbs
  • 665 Units in Stock
  • Manufactured by: Panran


 

03/04/2019
JOHAN W.
5 of 5 Stars
this calibrator not bad, satisfied again. thanks guys

 

 

Panran Measurement and Control Science and Technology Co.Ltd(Changsha Panran Commerce and Trade Co., Ltd is the foreign trade office) is the member of Chinese national temperature measurement technology committee. Panran is the most professional manufacturer in temperature and pressure measurement tools and instruments' calibration field in China. We own temperature and pressure calibration instruments production line, and research developing laboratories, and experienced soft-wares writers, besides, we also authorized to international manufacturing.

 


 


We are participated in many national measurement technical specification drafting, such as "JJF 1098-2003 Calibration Specification for Auto-Measure System of Thermocouples and Resistance Thermometers", "JJF ll71-2007 Calibration Specification for Temperature Itinerant Detecting Instrument" and "JJF ll84-2007 Testing Specification of Temperature Uniformity in Thermocouple Calibration Furnaces" and so on. We have established some big temperature and pressure research laboratories to improve the temperature and pressure accurancy in many cities of China. Panran passed ISO9001:2015 Quality Management Certificate. We are High-Tech Enterprice certificated and get the sponsored funds from Chinese official office. Some products passed CE and SGS certificates and enter the international market. We win high reputation in China and many other countries, such as Poland, Brazil, Iran, Egypt, Vietnam, Russia,Sri Lanka, Colombia, Malaysia, Indonesia, Saudi Arabia, Pakistan, Philippines

 


 


Panran main products are temperature calibration instruments, presure calibration instruments and automatic calibration system sofewares. Our "ZRJ intelligent thermotechnic instrument calibration system", "KRJ wide temperature field thermocouple calibration furnace" and "PR600 series heat pipe thermostatic bath" etc. are independently developed by us, and they are keeping first lever technical position in China. PANRAN products are widely used in military-industrial complex system ( including aviation, aerospace, weapons, nuclear energy, ship ), measurement and calibration institutions, rolling stock, machinery, metallurgy, electric power, petroleum, chemical industry, instruments and meters industry etc. 

 


 


Products' quality is the basis of surviving, and satisfying customers' requirements is our mission. Panran is young but very energetic, and our all staff warmly welcome you and your company to come to us for an co-operation in near future. Panran making is more accuracy! Thanks very much!

 


 






COPYRIGHT © 2019 PANRAN